DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
COIL QUANTITY | 1 |
CRITICALITY CODE JUSTIFICATION | FEAT |
CUBIC MEASURE | 0.030 CUBIC INCHES |
ENVIRONMENTAL PROTECTION | HERMETIC AND SALT SPRAY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
FEATURES PROVIDED | LATCHING CONTACTS |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES DC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 200.0 MILLIAMPERES DC INDUCTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC AND 1.0 AMPERES DC RESISTIVE LOAD |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
OVERALL DIAMETER | 0.370 INCHES MAXIMUM |
OVERALL LENGTH | 0.280 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
PURPOSE FOR WHICH DESIGNED | GENERAL |
SPECIAL FEATURES | FAILURE RATE LEVEL OF 0.100 PERCENT PER TEN THOUSAND CYCLES |
WINDING DC RESISTANCE RATING | 2.0 KILOHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/29 GOVERNMENT SPECIFICATION |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 10 PIN ALL FUNCTIONS |
TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
TIME DELAY | 0.002 SECONDS MAXIMUM FIXED OPERATE TIME |