Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
MIL-PRF-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS27400-30U96906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
CASE MATERIALMETAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.396 INCHES MINIMUM AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY
COIL QUANTITY1
CRITICALITY CODE JUSTIFICATIONFEAT
CUBIC MEASURE2.316 CUBIC INCHES
ENVIRONMENTAL PROTECTIONHERMETIC
FRAGILITY FACTORMODERATELY RUGGED
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE4.0 AMPERES AC AND 4.0 AMPERES DC MOTOR LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE8.0 AMPERES AC AND 8.0 AMPERES DC INDUCTIVE LOAD
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL HEIGHT1.335 INCHES MAXIMUM
OVERALL LENGTH1.718 INCHES MAXIMUM
OVERALL WIDTH1.010 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 SLOTTED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERNRECTANGULAR SINGLE MOUNTING FACILITY
MOUNTING SLOT WIDTH0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY
NOMINAL OPERATING CURRENT RATING AND TYPE120.0 MILLIAMPERES DC SINGLE WINDING
NONPILE-UP MAIN CONTACT ARRANGEMENT4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
PURPOSE FOR WHICH DESIGNEDGENERAL
SPECIAL FEATURESFAILURE RATE LEVEL 0.5 PERCENT
WINDING QUANTITY1
SPECIFICATION/STANDARD DATA96906-MS27400 GOVERNMENT STANDARD
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY14 WIRE HOOK ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.015 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME