NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND |
| 10.0 AMPERES DC RESISTIVE LOAD |
| 8.0 AMPERES AC AND |
| 6.0 AMPERES DC INDUCTIVE LOAD |
| 2.0 AMPERES AC AND |
| 2.0 AMPERES DC LAMP LOAD |
| 4.0 AMPERES AC AND |
| 4.0 AMPERES DC MOTOR LOAD |
ARC QUENCHING METHOD | AIR |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 100.0 OHMS NOMINAL SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
TERMINAL TYPE AND QUANTITY | 11 WIRE HOOK ALL FUNCTIONS |
TIME DELAY | 0.006 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC |
OVERALL LENGTH | 1.280 INCHES MAXIMUM |
OVERALL WIDTH | 0.940 INCHES MAXIMUM |
OVERALL HEIGHT | 0.810 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOTTED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.078 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.405 INCHES NOMINAL SINGLE MOUNTING FACILITY |
MOUNTING SLOT WIDTH | 0.133 INCHES NOMINAL SINGLE MOUNTING FACILITY |
PURPOSE FOR WHICH DESIGNED | GENERAL |
CUBIC MEASURE | 0.974 CUBIC INCHES |
FRAGILITY FACTOR | MODERATELY RUGGED |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CASE MATERIAL | METAL |