DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
CASE MATERIAL | METAL |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.396 INCHES MINIMUM AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
CUBIC MEASURE | 1.493 CUBIC INCHES |
ENVIRONMENTAL PROTECTION | HERMETIC |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC INDUCTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES AC MOTOR LOAD |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 1.655 INCHES MAXIMUM |
OVERALL LENGTH | 1.718 INCHES MAXIMUM |
OVERALL WIDTH | 0.525 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
PURPOSE FOR WHICH DESIGNED | GENERAL |
WINDING DC RESISTANCE RATING | 1.04 KILOHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 5 WIRE HOOK ALL FUNCTIONS |
TIME DELAY | 0.015 SECONDS MAXIMUM FIXED OPERATE TIME |
TIME DELAY | 0.05 SECONDS MAXIMUM FIXED RELEASE TIME |