5945-01-203-6835 RELAY,ELECTROMAGNETIC Index 5945-01-203-6837 RELAY,ELECTROMAGNETIC

National Stock Number:
5945-01-203-6836

Federal Supply Class:
5945

National Item Identification Number:
012036836

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
10138309A486GNIMIKKEISTOKESKUS NCB FINLAND
25485-41034K0662LEONARDO MW LTD
25485-41034U6682LEONARDO UK LTD
538113-7396214RAYTHEON COMPANY
M39016/9-006L81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39016/9-062L81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39016/981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39016/981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
CASE MATERIALMETAL
COIL QUANTITY1
CRITICALITY CODE JUSTIFICATIONFEAT
ENVIRONMENTAL PROTECTIONHERMETIC
FRAGILITY FACTORMODERATELY RUGGED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE100.0 MILLIAMPERES DC LAMP LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE200.0 MILLIAMPERES DC INDUCTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE250.0 MILLIAMPERES AC AND 1.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER0.370 INCHES MAXIMUM
OVERALL LENGTH0.280 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY1 TERMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
PURPOSE FOR WHICH DESIGNEDSPECIFIC
SPECIAL FEATURESFAILURE RATE LEVEL 3.0 PERCENT
SPECIFICATION/STANDARD DATA81349-MIL-R-39016/9 GOVERNMENT SPECIFICATION
WINDING DC RESISTANCE RATING1.56 KILOHMS NOMINAL SINGLE WINDING
WINDING QUANTITY1
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY8 WIRE LEAD ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.0015 SECONDS MAXIMUM FIXED RELEASE TIME
TIME DELAY0.002 SECONDS MAXIMUM FIXED OPERATE TIME


Click here to Register for Free 30-day Trial