DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
CASE MATERIAL | METAL |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | HERMETIC |
FEATURES PROVIDED | POLARIZED |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC AND 4.0 AMPERES DC MOTOR LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES AC AND 8.0 AMPERES DC INDUCTIVE LOAD |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 2.986 INCHES NOMINAL |
OVERALL LENGTH | 1.290 INCHES MAXIMUM |
OVERALL WIDTH | 1.250 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
NOMINAL OPERATING CURRENT RATING AND TYPE | 150.0 MILLIAMPERES DC SINGLE WINDING |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
PURPOSE FOR WHICH DESIGNED | GENERAL |
SPECIAL FEATURES | ONE TERMINAL FOR CONTROL VOLTAGE |
WINDING QUANTITY | 1 |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 1 PIN GROUND |
TERMINAL TYPE AND QUANTITY | 9 PIN ENERGIZING ELEMENT AND CONTACTS |
TIME DELAY | 0.01 SECONDS MAXIMUM FIXED OPERATE TIME |
TIME DELAY | 10.00 SECONDS NOMINAL FIXED RELEASE TIME |