DUTY TYPE | CONTINUOUS |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 750.0 MILLIAMPERES AC AND 750.0 MILLIAMPERES DC LAMP LOAD |
AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.687 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND VIBRATION RESISTANT AND HERMETIC |
FREQUENCY IN HERTZ | 50.0 MINIMUM AND 60.0 MAXIMUM |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC AND 25.0 AMPERES DC MOTOR LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC AND 25.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 124.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 4.576 INCHES MAXIMUM |
OVERALL LENGTH | 3.700 INCHES MAXIMUM |
OVERALL WIDTH | 3.305 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
NOMINAL OPERATING CURRENT RATING AND TYPE | 225.0 MILLIAMPERES AC SINGLE WINDING |
NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION AND 1 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
SPECIFICATION/STANDARD DATA | 96906-MS24143 GOVERNMENT STANDARD |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 12 THREADED STUD ALL FUNCTIONS |
TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
TIME DELAY | 0.03 SECONDS MAXIMUM FIXED OPERATE TIME |
TIME DELAY | 0.065 SECONDS MAXIMUM FIXED RELEASE TIME |
UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL SINGLE MOUNTING FACILITY |