NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 200.0 MILLIAMPERES AC AND |
| 3.0 AMPERES DC RESISTIVE LOAD |
| 500.0 MILLIAMPERES DC LAMP LOAD |
ARC QUENCHING METHOD | AIR |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 140.0 OHMS NOMINAL SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
TIME DELAY | 0.005 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC |
OVERALL LENGTH | 0.800 INCHES MAXIMUM |
OVERALL WIDTH | 0.400 INCHES MAXIMUM |
OVERALL HEIGHT | 1.412 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.412 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.112 INCHES SINGLE MOUNTING FACILITY |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 40 SINGLE MOUNTING FACILITY |
THREAD LENGTH | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
PURPOSE FOR WHICH DESIGNED | GENERAL |
FRAGILITY FACTOR | MODERATELY RUGGED |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CONTACT MATERIAL | SILVER |
CONTACT SURFACE TREATMENT | GOLD |
CASE MATERIAL | METAL |
PRECIOUS MATERIAL | SILVER AND |
| GOLD |
PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER AND |
| CONTACT SURFACES GOLD |