5945-01-067-0798 RELAY,ELECTROMAGNETIC Index 5910-01-067-0800 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5945-01-067-0799

Federal Supply Class:
5945

National Item Identification Number:
010670799

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
M39016/8-01381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M5757-39-00581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39016/881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39016/881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILR5757-3981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY TYPECONTINUOUS
CASE MATERIALMETAL
COIL QUANTITY2
ENVIRONMENTAL PROTECTIONHERMETIC
FRAGILITY FACTORMODERATELY RUGGED
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE100.0 MILLIAMPERES DC LAMP LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE500.0 MILLIAMPERES DC RESISTIVE LOAD
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP5.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS
OVERALL DIAMETER0.335 INCHES MAXIMUM
OVERALL LENGTH0.280 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY1 TERMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
WINDING DC RESISTANCE RATING61.0 OHMS NOMINAL ALL WINDINGS
WINDING QUANTITY2
SPECIFICATION/STANDARD DATA81349-MIL-R-39016/8 GOVERNMENT SPECIFICATION
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY7 WIRE LEAD ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.0015 SECONDS MAXIMUM FIXED OPERATE TIME