DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.062 INCHES MINIMUM AND 1.078 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
CRITICALITY CODE JUSTIFICATION | FEAT |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 160.0 MILLIAMPERES DC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES DC INDUCTIVE LOAD |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 0.410 INCHES MAXIMUM |
OVERALL LENGTH | 1.320 INCHES MAXIMUM |
OVERALL WIDTH | 0.410 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
MOUNTING SLOT WIDTH | 0.118 INCHES MINIMUM AND 0.122 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
PURPOSE FOR WHICH DESIGNED | GENERAL |
SPECIAL FEATURES | FAILURE RATE 1.0 PERCENT PER 10000 OPERATIONS |
WINDING DC RESISTANCE RATING | 700.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/22 GOVERNMENT SPECIFICATION |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
TIME DELAY | 0.005 SECONDS NOMINAL FIXED OPERATE AND RELEASE TIME |