5998-01-058-9936 CIRCUIT CARD ASSEMBLY Index 5945-01-058-9941 RELAY,REED

National Stock Number:
5945-01-058-9939

Federal Supply Class:
5945

National Item Identification Number:
010589939

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
KCL-D4A-00258657LEACH INTERNATIONAL CORP
MIL-PRF-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS27742-296906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
CASE MATERIALMETAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE1.396 INCHES MINIMUM AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY
COIL QUANTITY2
CUBIC MEASURE2.254 CUBIC INCHES
ENVIRONMENTAL PROTECTIONHERMETIC
FEATURES PROVIDEDLATCHING CONTACTS AND POLARIZED
FRAGILITY FACTORMODERATELY RUGGED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE10.0 AMPERES AC AND 10.0 AMPERES DC MOTOR LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE15.0 AMPERES AC AND 12.0 AMPERES DC INDUCTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE25.0 AMPERES AC AND 25.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE5.0 AMPERES AC AND 5.0 AMPERES DC LAMP LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS
OVERALL HEIGHT1.280 INCHES MAXIMUM
OVERALL LENGTH1.718 INCHES MAXIMUM
OVERALL WIDTH1.025 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY3 SLOTTED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERNTRIANGLE SINGLE MOUNTING FACILITY
MOUNTING SLOT WIDTH0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY
NOMINAL OPERATING CURRENT RATING AND TYPE75.0 MILLIAMPERES DC ALL WINDINGS
NONPILE-UP MAIN CONTACT ARRANGEMENT3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
PRECIOUS MATERIAL AND LOCATIONTERMINAL SURFACES GOLD
PRECIOUS MATERIALGOLD
PURPOSE FOR WHICH DESIGNEDSPECIFIC
WINDING QUANTITY2
SPECIFICATION/STANDARD DATA96906-MS27742 GOVERNMENT STANDARD
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY13 PIN ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.015 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME


Click here to Register for Free 30-day Trial