DUTY TYPE | CONTINUOUS |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | HERMETIC |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 300.0 MILLIAMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 0.617 INCHES MAXIMUM |
OVERALL LENGTH | 0.810 INCHES MAXIMUM |
OVERALL WIDTH | 0.410 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
WINDING DC RESISTANCE RATING | 700.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/6 GOVERNMENT SPECIFICATION |
TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |