5945-01-033-1532 RELAY,ELECTROMAGNETIC Index 6625-01-033-1534 LEAD,TEST

National Stock Number:
5945-01-033-1533

Federal Supply Class:
5945

National Item Identification Number:
010331533

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
86-73900-33914170HUGHES MISSILE SYSTEMS CO SAN DIEGO
86-73900-33915090RAYTHEON COMPANY
A003-S062-256623MICROSEMI CORP.-POWER MANAGEMENT GROUP
E618B56623MICROSEMI CORP.-POWER MANAGEMENT GROUP


Techincal Specification:
DUTY TYPECONTINUOUS
COIL QUANTITY2
ENVIRONMENTAL PROTECTIONHERMETIC
FEATURES PROVIDEDPOLARIZED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE10.0 AMPERES DC AND 10.0 AMPERES AC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS32.0 DC AND 115.0 AC
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP30.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL LENGTH2.750 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERNRECTANGULAR SINGLE MOUNTING FACILITY
NOMINAL OPERATING CURRENT RATING AND TYPE200.0 MILLIAMPERES DC SINGLE WINDING
NOMINAL THREAD SIZE0.138 INCHES SINGLE MOUNTING FACILITY
SPECIAL FEATURESMTG STUDS 0.375 IN. LG ON 1.625 IN. BY 1.750 IN. MTG CENTERS
WINDING QUANTITY1
THREAD CLASS2A SINGLE MOUNTING FACILITY
THREAD SERIES DESIGNATORUNC SINGLE MOUNTING FACILITY
TIME DELAY0.90 SECONDS MINIMUM AND 16.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME