National Stock Number: 5945-01-027-3886
Federal Supply Class: 5945
National Item Identification Number: 010273886
Description: RELAY,ELECTROMAGNETIC
Detail: A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
|
Manufacturer Information:
J422DD-26WL | 11532 | TELEDYNE DEFENSE ELECTRONICS, LLC | M39016/30-018L | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | MILR39016-30 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M |
|
Techincal Specification:
DUTY TYPE | CONTINUOUS | COIL QUANTITY | 2 | ENVIRONMENTAL PROTECTION | HERMETIC | FEATURES PROVIDED | POLARIZED AND LATCHING CONTACTS | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 200.0 MILLIAMPERES DC RESISTIVE LOAD | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC | OVERALL DIAMETER | 0.370 INCHES MAXIMUM | OVERALL LENGTH | 0.280 INCHES NOMINAL | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS ALL WINDINGS | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/30 GOVERNMENT SPECIFICATION | WINDING DC RESISTANCE RATING | 2.0 KILOHMS NOMINAL ALL WINDINGS | WINDING QUANTITY | 2 | TERMINAL TYPE AND QUANTITY | 10 PIN ALL FUNCTIONS | TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). | TIME DELAY | 0.01 SECONDS MAXIMUM FIXED OPERATE TIME |
|
|