DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
COIL QUANTITY | 1 |
CUBIC MEASURE | 0.461 CUBIC INCHES |
ENVIRONMENTAL PROTECTION | HERMETIC AND SHOCK RESISTANT AND VIBRATION RESISTANT |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 26.5 DC |
OVERALL HEIGHT | 0.790 INCHES NOMINAL |
OVERALL LENGTH | 0.990 INCHES NOMINAL |
OVERALL WIDTH | 0.590 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
PURPOSE FOR WHICH DESIGNED | GENERAL |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
WINDING DC RESISTANCE RATING | 500.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
TIME DELAY | 0.007 SECONDS MAXIMUM FIXED RELEASE TIME |
TIME DELAY | 0.008 SECONDS MAXIMUM FIXED OPERATE TIME |