NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND |
| 3.0 AMPERES DC RESISTIVE LOAD |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 600.0 OHMS NOMINAL SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | SHOCK RESISTANT |
OVERALL LENGTH | 1.330 INCHES MAXIMUM |
OVERALL WIDTH | 0.400 INCHES MAXIMUM |
OVERALL HEIGHT | 0.921 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.073 INCHES NOMINAL SINGLE MOUNTING FACILITY |
UNTHREADED MOUNTING HOLE DIAMETER | 0.120 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CUBIC MEASURE | 0.489 CUBIC INCHES |
CASE MATERIAL | METAL |