DUTY TYPE | CONTINUOUS |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 2 |
ENVIRONMENTAL PROTECTION | HERMETIC |
FEATURES PROVIDED | LATCHING CONTACTS |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC AND 25.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
OVERALL HEIGHT | 3.620 INCHES NOMINAL |
OVERALL LENGTH | 4.250 INCHES NOMINAL |
OVERALL WIDTH | 3.000 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.190 INCHES SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 27.5 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
WINDING DC RESISTANCE RATING | 75.0 OHMS NOMINAL ALL WINDINGS |
WINDING QUANTITY | 2 |
TERMINAL TYPE AND QUANTITY | 12 PIN ALL FUNCTIONS |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNF SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
TIME DELAY | 0.035 SECONDS MAXIMUM FIXED OPERATE TIME |