DUTY TYPE | CONTINUOUS |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.844 INCHES NOMINAL SECOND MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | HERMETIC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC AND 3.0 AMPERES DC INDUCTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
OVERALL HEIGHT | 2.156 INCHES NOMINAL |
OVERALL LENGTH | 2.187 INCHES MAXIMUM |
OVERALL WIDTH | 1.531 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL FIRST MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED HOLE SECOND MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | TRIANGLE SECOND MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.164 INCHES SECOND MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 6 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 20 PIN ALL FUNCTIONS |
THREAD CLASS | 2B SECOND MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |