DUTY TYPE | CONTINUOUS |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
FSC APPLICATION DATA | RELAY,ARMATURE,EXCEPT ENGINE |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC AND 3.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
OVERALL HEIGHT | 1.230 INCHES NOMINAL |
OVERALL LENGTH | 2.180 INCHES NOMINAL |
OVERALL WIDTH | 1.090 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
NOMINAL OPERATING CURRENT RATING AND TYPE | 80.0 MILLIAMPERES DC SINGLE WINDING |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2C |
WINDING DC RESISTANCE RATING | 300.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
TIME DELAY | 0.003 SECONDS NOMINAL FIXED RELEASE TIME |
TIME DELAY | 0.012 SECONDS NOMINAL FIXED OPERATE TIME |