DUTY TYPE | CONTINUOUS |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | HERMETIC |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.5 AMPERES AC RESISTIVE LOAD |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 48.0 VOLTS AC 25 DEG CELSIUS ALL WINDINGS |
OVERALL HEIGHT | 2.310 INCHES NOMINAL |
OVERALL LENGTH | 1.500 INCHES NOMINAL |
OVERALL WIDTH | 1.500 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
NOMINAL OPERATING CURRENT RATING AND TYPE | 53.5 MILLIAMPERES AC ALL WINDINGS |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
WINDING DC RESISTANCE RATING | 250.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 5 PIN ALL FUNCTIONS |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |