DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | NITROGEN |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.062 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.062 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | HERMETIC |
FREQUENCY IN HERTZ | 60.0 NOMINAL |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 3.500 INCHES NOMINAL |
OVERALL LENGTH | 2.500 INCHES NOMINAL |
OVERALL WIDTH | 2.500 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2A1B |
UNTHREADED MOUNTING HOLE DIAMETER | 0.169 INCHES NOMINAL SINGLE MOUNTING FACILITY |
WINDING DC RESISTANCE RATING | 100.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |