CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CONTACT STIMULUS RATING | 0.42 ACTUATION POINT MAXIMUM GALLONS PER MINUTE |
CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SINGLE VOLTAGE |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
OPERATING TEMP RATING | 0.0 CELSIUS MINIMUM AND 65.0 CELSIUS MAXIMUM |
OVERALL HEIGHT | 2.700 INCHES MAXIMUM |
OVERALL LENGTH | 2.970 INCHES NOMINAL |
OVERALL WIDTH | 1.150 INCHES MINIMUM AND 1.250 INCHES MAXIMUM |
MEDIA FOR WHICH DESIGNED | LIQUID |
MOUNTING METHOD | INPUT PORT |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
SPECIAL FEATURES | INLET AND OUTLET TUBE SIZE - 0.500 INCHES, BOTH; CONTACT RATING: FROM 10 MILLIAMPERES TO 500 MILLIAMPERES AND FROM 6 VDC TO 30 VDC IN ANY COMBINATION OF CURRENT AND VOLTAGE; DESIGNED FOR USE WITH HIGH PURITY DEMINERALIZED WATER |
STYLE DESIGNATOR | CYLINDRICAL W/LUGS |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |