CONTACT LOAD CURRENT RATING | 75.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL |
CONTACT LOAD CURRENT RATING | 30.0 MILLIAMPERES INDUCTIVE LOAD AND 100.0 MILLIAMPERES LAMP LOAD AND 200.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL |
CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES SINGLE SECTION REAR |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL |
CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
INDIVIDUAL SECTION QUANTITY | 1 |
OPERATING TEMP RANGE | -65.0 TO 85.0 CELSIUS |
OVERALL DIAMETER | 0.495 INCHES MINIMUM AND 0.515 INCHES MAXIMUM |
OVERALL LENGTH | 1.326 INCHES NOMINAL |
MOUNTING METHOD | THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.250 INCHES SINGLE MOUNTING FACILITY |
NONDEFINITIVE SPEC/STD DATA | K TYPE |
POLE QUANTITY | 1 SINGLE SECTION REAR |
SHAFT TYPE | ROUND, SLOTTED SINGLE ACTUATOR |
SPECIAL FEATURES | CLOSED CONSTRUCTION, FLUX SEAL, LOW LEVEL CAPABILITY, NO SHAFT GROUDING |
SPECIFICATION/STANDARD DATA | 81349-MIL-S-3786/20H GOVERNMENT SPECIFICATION |
STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
SWITCH ACTUATOR INDEXING POSITION QUANTITY | 10 SINGLE ACTUATOR |
SWITCH ACTUATOR POSITIONING INCREMENT | 36.0 DEGREES SINGLE ACTUATOR |
SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
TERMINAL TYPE | PRINTED CIRCUIT |
THREAD LENGTH | 0.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNF SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 28 SINGLE MOUNTING FACILITY |
THROW QUANTITY | 10 SINGLE SECTION REAR |