CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CONTACT LOAD CURRENT RATING | 5.8 AMPERES RESISTIVE LOAD FIRST VOLTAGE2.9 AMPERES RESISTIVE LOAD SECOND VOLTAGE2.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CONTACT STIMULUS RATING | 415.00 ACTUATION POINT MINIMUM POUNDS PER SQUARE INCH GAGE AND 435.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH GAGE AND 290.00 DEACTUATION POINT MINIMUM POUNDS PER SQUARE INCH GAGE AND 310.00 DEACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH GAGE |
CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE240.0 AC AT SEA LEVEL SECOND VOLTAGE28.0 DC AT SEA LEVEL THIRD VOLTAGE |
FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE60.0 SECOND VOLTAGE |
OPERATING TEMP RATING | -20.0 FAHRENHEIT MINIMUM AND 150.0 FAHRENHEIT MAXIMUM |
OVERALL LENGTH | 3.180 INCHES NOMINAL |
MEDIA FOR WHICH DESIGNED | GAS |
MOUNTING METHOD | INLET CONNECTION |
PRESSURE SWITCH TYPE | GAGE |
PROOF PRESSURE | 600.00 POUNDS PER SQUARE INCH GAGE |
SENSING ELEMENT BURST PRESSURE | 3500.00 POUNDS PER SQUARE INCH GAGE |
WIDTH ACROSS FLATS | 0.563 INCHES NOMINAL |
STYLE DESIGNATOR | CYLINDRICAL W/FLANGE |
TERMINAL TYPE | WIRE LEAD |