CONTACT ADJUSTMENT RANGE | +800.00 TO 1800.00 ACTUATION POINT POUNDS PER SQUARE INCH GAGE |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET |
CONTACT LOAD CURRENT RATING | 4.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 28.0 AC AT SEA LEVEL SINGLE VOLTAGE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
OPERATING TEMP RATING | -2.0 CELSIUS MINIMUM AND 35.0 CELSIUS MAXIMUM |
OVERALL DIAMETER | 1.380 INCHES MAXIMUM |
OVERALL LENGTH | 3.500 INCHES MAXIMUM |
MEDIA FOR WHICH DESIGNED | GAS |
MOUNTING METHOD | BOLT |
PRESSURE SWITCH TYPE | ABSOLUTE |
PROOF PRESSURE | 3000.00 POUNDS PER SQUARE INCH GAGE |
STYLE DESIGNATOR | CYLINDRICAL |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |