National Stock Number: 5930-01-260-2314
Federal Supply Class: 5930
National Item Identification Number: 012602314
Description: SWITCH,PROXIMITY
Detail: A SWITCH DESIGNED TO PERFORM THE FUNCTION OF OPENING AND/OR CLOSING ONE OR MORE ELECTRICAL CIRCUITS. THE SWITCHING FUNCTION IS ACCOMPLISHED BY MEANS OF SEPARABLE CONTACTS, SEMICONDUCTOR DEVICES, OR A COMBINATION OF SEPARABLE CONTACTS AND SEMICONDUCTOR DEVICES. THE ITEM FUNCTIONS IN RESPONSE TO ELECTRICAL CHANGES IN ITS INTERNAL CIRCUIT CAUSED BY CAPACITANCE, INDUCTANCE, OR MAGNETIC FLUX CHANGES. IT IS ACTIVATED BY PERMANENT MAGNETS, METALLIC MATERIALS, OR NONMETALLIC MATERIALS WHICH COME WITHIN ITS SENSING RANGE. FOR SENSING SWITCHES WHICH RESPOND TO CHANGES OTHER THAN CAPACITANCE, INDUCTANCE, OR MAGNETIC FLUX, SEE SWITCH, AIRFLOW; SWITCH, CENTRIFUGAL; SWITCH, INERTIA; SWITCH, PRESSURE; SWITCH, PRESSURE-THERMOSTATIC; SWITCH, THERMOSTATIC; AND SWITCH, TILT.
|
Manufacturer Information:
713660 | 04553 | TOPWORX INC | 74-13528-A1 | 04553 | TOPWORX INC | 74-13528-A2 | 04553 | TOPWORX INC | PL14341205-60 | 0DHG4 | GULF COAST HOLDINGS INC DBA UNIDYNAMICS |
|
Techincal Specification:
CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL FIRST VOLTAGE250.0 DC AT SEA LEVEL SECOND VOLTAGE | PROPRIETARY CHARACTERISTICS | PACS | MOUNTING METHOD | THREADED BUSHING | NOMINAL THREAD SIZE | 0.625 INCHES SINGLE THREADED BUSHING | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY | OPERATING TEMP RATING | -22.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM | OVERALL DIAMETER | 0.625 INCHES NOMINAL | OVERALL LENGTH | 2.770 INCHES NOMINAL | SPECIAL FEATURES | SENSING DISTANCE IS 0.094 IN. FROM SENSING AREA | STYLE DESIGNATOR | CYLINDRICAL | TERMINAL TYPE | WIRE LEAD | THREAD CLASS | 2B SINGLE THREADED BUSHING | THREAD SERIES DESIGNATOR | UNF SINGLE THREADED BUSHING | CONTACT ACTION STIMULUS | INCREASE | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
|
|