5930-01-208-6295 SWITCH,THERMOSTATIC Index 5905-01-208-6297 RESISTOR ASSEMBLY

National Stock Number:
5930-01-208-6296

Federal Supply Class:
5930

National Item Identification Number:
012086296

Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
222-10NL-222221119278DETROIT SWITCH INC
NF9-2009288234UNITED ELECTRIC CONTROLS COMPANY


Techincal Specification:
BODY HEIGHT2.750 INCHES NOMINAL
BULB DIAMETER0.375 INCHES NOMINAL
BULB LENGTH4.500 INCHES NOMINAL
CAPILLARY TUBE LENGTH252.0 INCHES NOMINAL
CONTACT ADJUSTMENT RANGE+140.00 TO 215.00 ACTUATION POINT DEGREES FAHRENHEIT
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT TYPEEXTERNAL ACTUATION POINT HEX NUT
CONTACT LOAD CURRENT RATING4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE
CONTACT LOAD CURRENT RATING8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE
CONTACT LOAD CURRENT RATING9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE
CONTACT LOAD CURRENT RATING16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE
CONTACT LOAD CURRENT RATING2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE
CONTACT LOAD CURRENT RATING2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE
CONTACT LOAD CURRENT RATING3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE
CONTACT LOAD CURRENT RATING4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS115.0 AC AT SEA LEVEL FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS115.0 DC AT SEA LEVEL FIFTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS230.0 DC AT SEA LEVEL SIXTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS230.0 AC AT SEA LEVEL SECOND VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS440.0 AC AT SEA LEVEL THIRD VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS440.0 DC AT SEA LEVEL SEVENTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS550.0 AC AT SEA LEVEL FOURTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS550.0 DC AT SEA LEVEL EIGHTH VOLTAGE
FEATURES PROVIDEDELECTRICAL ACCESS PORT
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONVIBRATION RESISTANT AND WATERTIGHT
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS2.406 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS3.281 INCHES NOMINAL
OPERATING TEMP RATING271.0 FAHRENHEIT MAXIMUM
OVERALL HEIGHT5.031 INCHES NOMINAL
OVERALL LENGTH5.188 INCHES NOMINAL
OVERALL WIDTH2.812 INCHES NOMINAL
MEDIA FOR WHICH DESIGNEDLIQUID
MOUNTING FACILITY PATTERNISOSCELES TRIANGLE
MOUNTING METHODBRACKET AND UNTHREADED HOLE
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
PRECIOUS MATERIAL AND LOCATIONCONTACTS SILVER
PRECIOUS MATERIALSILVER
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS0.656 INCHES NOMINAL
STYLE DESIGNATORRECTANGULAR
TEMP SENSING ELEMENT TYPECAPILLARY TUBE-BULB
TERMINAL TYPESCREW
UNTHREADED MOUNTING HOLE DIAMETER0.281 INCHES NOMINAL


Click here to Register for Free 30-day Trial