6640-01-202-2263 TIP,PIPET Index 5905-01-202-2265 RESISTOR,FIXED,WIRE WOUND

National Stock Number:
5930-01-202-2264

Federal Supply Class:
5930

National Item Identification Number:
012022264

Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
1211236-36056232LOCKHEED MARTIN CORPORATION
62308-182340L3HARRIS TECHNOLOGIES, INC.
M119017017282647SENSATA TECHNOLOGIES, INC.
M24236-1-036081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M24236/1-036081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-24236/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILS2423681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY DIAMETER0.640 INCHES MAXIMUM
BODY HEIGHT0.350 INCHES MINIMUM AND 0.395 INCHES MAXIMUM
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYDEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT LOAD CURRENT RATING2.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 500.0 MILLIAMPERES LAMP LOAD FIRST VOLTAGE
CONTACT LOAD CURRENT RATING5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE
CONTACT STIMULUS RATING20.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT AND 190.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 170.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT
CONTACT VOLTAGE RATING IN VOLTS115.0 AC AT SEA LEVEL FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS28.0 DC AT SEA LEVEL SECOND VOLTAGE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.937 INCHES NOMINAL
FREQUENCY IN HERTZ60.0 FIRST VOLTAGE
OVERALL HEIGHT0.708 INCHES NOMINAL
OVERALL LENGTH1.200 INCHES MINIMUM AND 1.260 INCHES MAXIMUM
MEDIA FOR WHICH DESIGNEDGAS OR LIQUID
MOUNTING FACILITY PATTERNTWO POSITION IN-LINE
MOUNTING METHODBRACKET
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
SPECIFICATION/STANDARD DATA81349-MILS24236/1 GOVERNMENT SPECIFICATION
STYLE DESIGNATORDISC W/FLANGE
TEMP SENSING ELEMENT TYPEINTERNAL SENSOR
TERMINAL TYPETAB, SOLDER LUG
TEST DATA DOCUMENT81349-MILS24236 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).