BODY HEIGHT | 3.812 INCHES NOMINAL |
CONTACT ADJUSTMENT RANGE | +75.00 TO 200.00 ACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB |
CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL FIRST VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SECOND VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 480.0 AC AT SEA LEVEL THIRD VOLTAGE |
FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERTIGHT |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.906 INCHES NOMINAL |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.438 INCHES NOMINAL |
OVERALL HEIGHT | 8.281 INCHES NOMINAL |
OVERALL LENGTH | 2.906 INCHES NOMINAL |
OVERALL WIDTH | 2.375 INCHES NOMINAL |
MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
MOUNTING FACILITY PATTERN | TWO POSITION DIAGONAL |
MOUNTING METHOD | BOLT AND THREADED BUSHING |
NOMINAL THREAD SIZE | 0.164 INCHES ALL BOLT |
NOMINAL THREAD SIZE | 0.750 INCHES SINGLE THREADED BUSHING |
NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
STYLE DESIGNATOR | RECTANGULAR |
TEMP SENSING ELEMENT TYPE | BULB |
TERMINAL TYPE | SCREW |
THREAD CLASS | 2A ALL BOLT |
THREAD SERIES DESIGNATOR | NPT SINGLE THREADED BUSHING |
THREAD SERIES DESIGNATOR | UNC ALL BOLT |
THREAD QUANTITY PER INCH | 14 SINGLE THREADED BUSHING |
THREAD QUANTITY PER INCH | 32 ALL BOLT |