BODY LENGTH | 0.170 INCHES NOMINAL |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE |
CONTACT STIMULUS RATING | 190.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 160.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
OPERATING TEMP RATING | -30.0 FAHRENHEIT MINIMUM AND 350.0 FAHRENHEIT MAXIMUM |
OVERALL LENGTH | 0.373 INCHES NOMINAL |
MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
MOUNTING METHOD | THREADED STUD |
NOMINAL THREAD SIZE | 0.250 INCHES ALL THREADED STUD |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
WIDTH ACROSS FLATS | 0.281 INCHES NOMINAL |
SPECIFICATION/STANDARD DATA | 81349-MIL-S-24236/19 GOVERNMENT SPECIFICATION |
STYLE DESIGNATOR | PLUG |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | TAB, SOLDER LUG |
TEST DATA DOCUMENT | 81349-MIL-S-24236 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
THREAD CLASS | 2A ALL THREADED STUD |
THREAD SERIES DESIGNATOR | UNF ALL THREADED STUD |
THREAD QUANTITY PER INCH | 28 ALL THREADED STUD |