BODY DIAMETER | 0.560 INCHES MINIMUM AND 0.640 INCHES MAXIMUM |
BODY HEIGHT | 0.280 INCHES MINIMUM AND 0.395 INCHES MAXIMUM |
CONTACT ACTION STIMULUS | DECREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 500.0 MILLIAMPERES LAMP LOAD FIRST VOLTAGE |
CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE |
CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD THIRD VOLTAGE |
CONTACT STIMULUS RATING | 30.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 15.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT ALTITUDE THIRD VOLTAGE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.937 INCHES NOMINAL |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
OPERATING TEMP RATING | -65.0 FAHRENHEIT MINIMUM AND 500.0 FAHRENHEIT MAXIMUM |
OVERALL HEIGHT | 0.453 INCHES MINIMUM AND 0.683 INCHES MAXIMUM |
OVERALL LENGTH | 1.190 INCHES MINIMUM AND 1.260 INCHES MAXIMUM |
MEDIA FOR WHICH DESIGNED | GAS |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
UNTHREADED MOUNTING HOLE DIAMETER | 0.140 INCHES NOMINAL |
SPECIFICATION/STANDARD DATA | 81349-MIL-S-24236/1 GOVERNMENT SPECIFICATION |
STYLE DESIGNATOR | DISC W/FLANGE |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | TAB, SOLDER LUG |
TEST DATA DOCUMENT | 81349-MIL-S-24236 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |