5905-01-042-8664 RESISTOR,FIXED,WIRE WOUND Index 5905-01-042-8666 RESISTOR,FIXED,WIRE WOUND,INDUCT

National Stock Number:
5930-01-042-8665

Federal Supply Class:
5930

National Item Identification Number:
010428665

Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
M24236/1-123081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-24236/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-24236/1K81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-S-24236/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-S-24236/1C81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY DIAMETER0.540 INCHES MINIMUM AND 0.640 INCHES MAXIMUM
BODY HEIGHT0.280 INCHES MINIMUM AND 0.395 INCHES MAXIMUM
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYDEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT LOAD CURRENT RATING2.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 500.0 MILLIAMPERES LAMP LOAD FIRST VOLTAGE
CONTACT LOAD CURRENT RATING5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE
CONTACT LOAD CURRENT RATING5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD THIRD VOLTAGE
CONTACT STIMULUS RATING140.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 125.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT
CONTACT VOLTAGE RATING IN VOLTS115.0 AC AT SEA LEVEL FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS28.0 DC AT SEA LEVEL SECOND VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS28.0 DC AT ALTITUDE THIRD VOLTAGE
CRITICALITY CODE JUSTIFICATIONFEAT
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.937 INCHES NOMINAL
FEATURES PROVIDEDHERMETICALLY SEALED CASE
FREQUENCY IN HERTZ60.0 FIRST VOLTAGE
OPERATING TEMP RATING-65.0 FAHRENHEIT MINIMUM AND 500.0 FAHRENHEIT MAXIMUM
OVERALL HEIGHT0.659 INCHES NOMINAL
OVERALL LENGTH1.160 INCHES MINIMUM AND 1.260 INCHES MAXIMUM
MEDIA FOR WHICH DESIGNEDGAS OR LIQUID
MOUNTING FACILITY PATTERNTWO POSITION IN-LINE
MOUNTING METHODBRACKET AND SLOT AND UNTHREADED HOLE
MOUNTING SLOT WIDTH0.140 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
SPECIAL FEATURESWEAPON SYSTEM ESSENTIAL
UNTHREADED MOUNTING HOLE DIAMETER0.140 INCHES NOMINAL
SPECIFICATION/STANDARD DATA81349-MIL-S-24236/1 GOVERNMENT SPECIFICATION
STYLE DESIGNATORDISC W/FLANGE
TEMP SENSING ELEMENT TYPEINTERNAL SENSOR
TERMINAL TYPETAB, SOLDER LUG
TEST DATA DOCUMENT81349-MIL-S-24236 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).