CONTACT LOAD CURRENT RATING | 50.0 MILLIAMPERES INDUCTIVE LOAD AND 500.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL |
CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES EACH SECTION REAR |
CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL |
FIRST FLAT LENGTH | 0.375 INCHES NOMINAL SINGLE ACTUATOR |
FLAT HEIGHT | 0.216 INCHES NOMINAL SINGLE ACTUATOR |
INDIVIDUAL SECTION QUANTITY | 4 |
OVERALL DIAMETER | 1.875 INCHES MAXIMUM |
OVERALL LENGTH | 3.748 INCHES NOMINAL |
MOUNTING METHOD | BRACKET 2ND MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.375 INCHES 1ST MOUNTING FACILITY |
NONTURN DEVICE TYPE | FLATTED BUSHING AT 1:30 O'CLOCK |
OPERATING TEMP RANGE | -65.0 TO 85.0 CELSIUS |
POLE QUANTITY | 1 EACH SECTION REAR |
SHAFT DIAMETER | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
SHAFT FLAT/SLOT ANGULAR LOCATION | 60.0 DEGREES FROM CONTACT POSITION 1 SINGLE ACTUATOR |
SHAFT LENGTH | 0.500 INCHES NOMINAL SINGLE ACTUATOR |
SHAFT TYPE | ROUND, FLATTED SINGLE ACTUATOR |
STYLE DESIGNATOR | CIRCULAR WAFER, BUSHING MOUNT |
SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
SWITCH ACTUATOR INDEXING POSITION QUANTITY | 14 SINGLE ACTUATOR |
SWITCH ACTUATOR POSITIONING INCREMENT | 20.0 DEGREES SINGLE ACTUATOR |
TERMINAL TYPE | TAB, SOLDER LUG |
THREAD CLASS | 2A 1ST MOUNTING FACILITY |
THREAD LENGTH | 0.312 INCHES NOMINAL 1ST MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNS 1ST MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 1ST MOUNTING FACILITY |
THROW QUANTITY | 13 EACH SECTION REAR |