ACTUATOR DIAMETER | 0.250 INCHES NOMINAL |
ACTUATOR FREE POSITION HEIGHT | 0.263 INCHES MINIMUM AND 0.289 INCHES MAXIMUM |
ACTUATOR HEIGHT | 0.406 INCHES NOMINAL |
ACTUATOR STYLE | ROUND |
BODY HEIGHT | 1.125 INCHES NOMINAL |
BODY LENGTH | 2.500 INCHES NOMINAL |
BODY STYLE | BUSHING/HOLE MOUNTED |
BODY WIDTH | 0.812 INCHES NOMINAL |
BUSHING LENGTH | 0.625 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.125 INCHES NOMINAL |
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.000 MILLIAMPERES RESISTIVE DC AND 15.000 AMPERES RESISTIVE AC |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SHOCK RESISTANT |
INCLOSURE TYPE | FULLY INCLOSED |
NOMINAL THREAD SIZE | 0.469 INCHES |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION SINGLE SWITCH UNIT |
MAXIMUM VOLTAGE RATING IN VOLTS | 110.0 AC AND 230.0 DC |
THREAD QUANTITY PER INCH | 32 |
THREAD SERIES DESIGNATOR | UNS |
SWITCH ACTUATING FORCE | 10.0 OUNCES MINIMUM AND 14.0 OUNCES MAXIMUM |
TERMINAL TYPE AND QUANTITY | 2 SCREW |