CONTACT ADJUSTMENT RANGE | -100.00 TO 400.00 ACTUATION POINT DEGREES FAHRENHEIT AND -100.00 TO 400.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT DIAL AND EXTERNAL ACTUATION POINT DIAL |
CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CONTACT STIMULUS RATING | 60.00 ACTUATION POINT NOMINAL DEGREES CELSIUS AND 55.00 DEACTUATION POINT NOMINAL DEGREES CELSIUS AND 5.00 DIFFERENTIAL POINT NOMINAL DEGREES CELSIUS |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL THIRD VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL FIRST VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL FOURTH VOLTAGE |
FEATURES PROVIDED | TAMPER PROOF CAP |
OVERALL DIAMETER | 3.750 INCHES NOMINAL |
OVERALL LENGTH | 6.405 INCHES NOMINAL |
MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
MOUNTING METHOD | THREADED BUSHING |
NOMINAL THREAD SIZE | 0.500 INCHES SINGLE THREADED BUSHING |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
WIDTH ACROSS FLATS | 0.875 INCHES NOMINAL |
STYLE DESIGNATOR | CYLINDRICAL |
TEMP SENSING ELEMENT TYPE | BULB |
TERMINAL TYPE | TAB W/SCREW |
THREAD LENGTH | 0.625 INCHES NOMINAL SINGLE THREADED BUSHING |
THREAD SERIES DESIGNATOR | UNS SINGLE THREADED BUSHING |
THREAD QUANTITY PER INCH | 14 SINGLE THREADED BUSHING |
BULB DIAMETER | 0.618 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
BULB LENGTH | 2.968 INCHES NOMINAL |
BODY LENGTH | 4.833 INCHES NOMINAL |