CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL |
CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES EACH SECTION PERIPHERY |
CONTACT VOLTAGE RATING IN VOLTS | 118.0 AC AT SEA LEVEL |
FIRST FLAT LENGTH | 0.560 INCHES NOMINAL SINGLE ACTUATOR |
FLAT HEIGHT | 0.219 INCHES NOMINAL SINGLE ACTUATOR |
INDIVIDUAL SECTION QUANTITY | 5 |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
OVERALL HEIGHT | 2.010 INCHES MAXIMUM |
OVERALL LENGTH | 7.000 INCHES NOMINAL |
OVERALL WIDTH | 2.350 INCHES MAXIMUM |
MOUNTING FACILITY PATTERN | FOUR POSITION DIAMOND SINGLE MOUNTING FACILITY |
MOUNTING METHOD | BRACKET AND THREADED HOLE SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
POLE QUANTITY | 2 EACH SECTION PERIPHERY |
SHAFT DIAMETER | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
SHAFT LENGTH | 0.620 INCHES NOMINAL SINGLE ACTUATOR |
SHAFT FLAT/SLOT ANGULAR LOCATION | 180.0 DEGREES FROM CONTACT POSITION 1 SINGLE ACTUATOR |
SHAFT TYPE | ROUND, FLATTED SINGLE ACTUATOR |
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
SHORTEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
SPECIAL FEATURES | CROSSTALK SHALL NOT EXCEED 40DB DOWN WITH 2000 OHMS BETWEEN TERMINALS AND GROUND AND A 2V RMS 2 KC SIGNAL APPLIED TO ANY TERMINAL |
STYLE DESIGNATOR | TAP, SQUARE FRAME |
SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
SWITCH ACTUATOR INDEXING POSITION QUANTITY | 7 SINGLE ACTUATOR |
SWITCH ACTUATOR STOP DEVICE TYPE | FIXED STOP SINGLE ACTUATOR |
TERMINAL TYPE | TURRET |
THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
THROW QUANTITY | 7 EACH SECTION PERIPHERY |
UNTHREADED MOUNTING HOLE DIAMETER | 0.138 INCHES NOMINAL SINGLE MOUNTING FACILITY |