BODY LENGTH | 1.510 INCHES NOMINAL |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CONTACT STIMULUS RATING | 270.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 280.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 25.00 DIFFERENTIAL POINT MINIMUM DEGREES FAHRENHEIT AND 35.00 DIFFERENTIAL POINT MAXIMUM DEGREES FAHRENHEIT |
CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 32.0 DC AT SEA LEVEL SECOND VOLTAGE |
FEATURES PROVIDED | INTERNALLY GROUNDED |
OVERALL LENGTH | 2.386 INCHES NOMINAL |
MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
MOUNTING METHOD | THREADED BUSHING |
NOMINAL THREAD SIZE | 0.375 INCHES SINGLE THREADED BUSHING |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
OPERATING TEMP RATING | -245.0 CELSIUS MINIMUM AND 275.0 FAHRENHEIT MAXIMUM |
WIDTH ACROSS FLATS | 0.688 INCHES NOMINAL |
STYLE DESIGNATOR | PLUG |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | QUICK DISCONNECT, MALE |
THREAD LENGTH | 0.525 INCHES NOMINAL SINGLE THREADED BUSHING |
THREAD QUANTITY PER INCH | 18 SINGLE THREADED BUSHING |
THREAD SERIES DESIGNATOR | PTF-SAE SHORT SINGLE THREADED BUSHING |