5930-00-660-4306 SWITCH,ROTARY Index 5930-00-660-4308 SWITCH,TOGGLE

National Stock Number:
5930-00-660-4307

Federal Supply Class:
5930

National Item Identification Number:
006604307

Description:
SWITCH,ROTARY

Detail:
A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).


Manufacturer Information:
165479210001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
165479236090LOCKHEED MARTIN LIBRASCOPE CORP
165479240931HONEYWELL INTERNATIONAL, INC
165479282121ELECTRO SWITCH CORP.


Techincal Specification:
CONTACT LOAD CURRENT RATING5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 2.5 AMPERES LAMP LOAD DC AT SEA LEVEL
CONTACT LOAD CURRENT RATING5.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL
CONTACT SWITCHING ACTIONBREAKS BEFORE MAKES EACH SECTION FRONT
CONTACT VOLTAGE RATING IN VOLTS115.0 AC AT SEA LEVEL
CONTACT VOLTAGE RATING IN VOLTS28.0 DC AT SEA LEVEL
FIRST FLAT LENGTH0.438 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT0.216 INCHES NOMINAL SINGLE ACTUATOR
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONDUSTPROOF
INDIVIDUAL SECTION QUANTITY10
OVERALL DIAMETER1.880 INCHES MAXIMUM
OVERALL LENGTH6.370 INCHES NOMINAL
MOUNTING METHODTHREADED BUSHING SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE0.375 INCHES SINGLE MOUNTING FACILITY
POLE QUANTITY1 EACH SECTION FRONT
SHAFT DIAMETER0.249 INCHES NOMINAL SINGLE ACTUATOR
SHAFT TYPEROUND, FLATTED SINGLE ACTUATOR
SHAFT LENGTH1.120 INCHES NOMINAL SINGLE ACTUATOR
STYLE DESIGNATORTAP, CIRCULAR, BUSHING MOUNT
SWITCH ACTUATOR INDEXING POSITION QUANTITY8 SINGLE ACTUATOR
SWITCH ACTUATOR POSITIONING INCREMENT45.0 DEGREES SINGLE ACTUATOR
SWITCH ACTUATOR STOP DEVICE TYPEFIXED STOP SINGLE ACTUATOR
SWITCH CONTACT BASIC DESIGNNONPILE-UP SYMMETRICAL
TERMINAL TYPETAB W/SCREW
THREAD CLASS2A SINGLE MOUNTING FACILITY
THREAD LENGTH0.469 INCHES NOMINAL SINGLE MOUNTING FACILITY
THREAD SERIES DESIGNATORUNEF SINGLE MOUNTING FACILITY
THROW QUANTITY7 EACH SECTION FRONT


Click here to Register for Free 30-day Trial