BODY DIAMETER | 0.640 INCHES MAXIMUM |
BODY HEIGHT | 0.500 INCHES MAXIMUM |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT LOAD CURRENT RATING | 1.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
CONTACT LOAD CURRENT RATING | 1.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CONTACT STIMULUS RATING | 310.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 330.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 30.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SECOND VOLTAGE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.007 INCHES NOMINAL |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
OPERATING TEMP RATING | -65.0 FAHRENHEIT MINIMUM AND 400.0 FAHRENHEIT MAXIMUM |
OVERALL HEIGHT | 1.340 INCHES MAXIMUM |
OVERALL LENGTH | 1.220 INCHES MINIMUM AND 1.280 INCHES MAXIMUM |
OVERALL WIDTH | 0.770 INCHES MINIMUM AND 0.830 INCHES MAXIMUM |
MEDIA FOR WHICH DESIGNED | GAS |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
MOUNTING METHOD | BRACKET |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
STYLE DESIGNATOR | DISC W/FLANGE |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | THREADED STUD |