5925-01-580-5744 INTERRUPTER,GROUND FAULT Index 5925-01-580-7207 CIRCUIT BREAKER

National Stock Number:
5925-01-580-7166

Federal Supply Class:
5925

National Item Identification Number:
015807166

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
AP1-1RC-65F-25281541SENSATA TECHNOLOGIES MARYLAND, INC


Techincal Specification:
AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS50.0 DC NOMINAL SINGLE LOCATION
BODY LENGTH1.562 INCHES MAXIMUM
BODY STYLESINGLE POLE TYPE
BODY WIDTH0.656 INCHES MAXIMUM
BUSHING LENGTH0.625 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.875 INCHES NOMINAL
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP W/REMOTE TRIP FEATURE SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
PART NAME ASSIGNED BY CONTROLLING AGENCYAP MAGNETIC CIRCUIT PROTECTOR
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE2.5 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS65.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE1.605 INCHES MAXIMUM
NOMINAL THREAD SIZE0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS50.0 DC SINGLE LOCATION
SPECIAL FEATURES50/60 HZ HIGH PULSE LONG TIME DELAY; INERTIAL DELAY; AUXILLIARY SWITCH
POLE QUANTITY1
RESET METHODMANUAL
TERMINAL TYPE AND QUANTITY2 WIRE HOOK
THREAD SERIES DESIGNATORUNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT10.000 NOMINAL AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
TRIP RELEASE DUTY CYCLECONTINUOUS SINGLE LOCATION
TRIP RELEASE METHODMAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT65.0 SINGLE LOCATION


Click here to Register for Free 30-day Trial