5925-01-566-7983 CIRCUIT BREAKER Index 5925-01-567-0044 CIRCUIT BREAKER

National Stock Number:
5925-01-566-8114

Federal Supply Class:
5925

National Item Identification Number:
015668114

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
AP1-1-50-50181541SENSATA TECHNOLOGIES MARYLAND, INC


Techincal Specification:
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE500.0 AMPERES DC SINGLE LOCATION
MOUNTING SURFACE TO TERMINAL END DISTANCE1.605 INCHES NOMINAL
POLE QUANTITY1
TRIP RELEASE METHODMAGNETIC SINGLE LOCATION
BODY LENGTH1.562 INCHES NOMINAL
BODY STYLESINGLE POLE TYPE
BODY WIDTH0.656 INCHES NOMINAL
BUSHING LENGTH0.380 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.875 INCHES NOMINAL
FREQUENCY IN HERTZ50.0 SINGLE LOCATION