5985-01-531-3412 ANTENNA Index 6685-01-531-3414 THERMOCOUPLE,HEATING ELEMENT

National Stock Number:
5925-01-531-3413

Federal Supply Class:
5925

National Item Identification Number:
015313413

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
710509KQ8BLUE SEAS SCUBA CENTER


Techincal Specification:
ACTUATOR FUNCTIONTRIP W/SEPARATE RESET
BODY LENGTH2.890 INCHES NOMINAL
BODY STYLESINGLE POLE TYPE
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.090 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.230 INCHES NOMINAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MATERIALPLASTIC CASE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE40.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS40.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE1.440 INCHES NOMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS42.0 DC SINGLE LOCATION
POLE QUANTITY1
RESET METHODMANUAL AND AUTOMATIC
TRIP RELEASE AMBIENT TEMP RATING82.0 CELSIUS MAXIMUM SINGLE LOCATION
TRIP RELEASE METHODTHERMAL SINGLE LOCATION


Click here to Register for Free 30-day Trial