National Stock Number: 5925-01-355-5715
Federal Supply Class: 5925
National Item Identification Number: 013555715
Description: CIRCUIT BREAKER
Detail: A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
|
Manufacturer Information:
APL-1-1-62-102-A | 81541 | SENSATA TECHNOLOGIES MARYLAND, INC | D-2283-7000 | D1870 | ROCKWELL-COLLINS DEUTSCHLAND GESCHAEFTSBEREICH DER ROCKWELL INTER GMBH |
|
Techincal Specification:
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC AND 65.0 DC SINGLE LOCATION | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.0 AMPERES AC SINGLE LOCATION | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 DC SINGLE LOCATION | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD | POLE QUANTITY | 1 | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION | TERMINAL TYPE AND QUANTITY | 4 THREADED STUD |
|