5925-01-214-4127 CIRCUIT BREAKER Index 5925-01-214-4129 CIRCUIT BREAKER

National Stock Number:
5925-01-214-4128

Federal Supply Class:
5925

National Item Identification Number:
012144128

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
2TC43-182647SENSATA TECHNOLOGIES, INC.
2TC61-182647SENSATA TECHNOLOGIES, INC.
454-0105-00394756THE BOEING COMPANY
454-0105-01594756THE BOEING COMPANY
935A239-183843SUNDSTRAND CORP ELECTRIC POWER SYSTEMS DIV
935A239-199167HAMILTON SUNDSTRAND CORPORATION
L454C2001-3-00343999THE BOEING COMPANY
L454C2001-3-01543999THE BOEING COMPANY


Techincal Specification:
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE ONE
ARC QUENCHING METHODAIR
AUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM
BODY LENGTH0.880 INCHES MAXIMUM
BODY WIDTH0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
BODY STYLESINGLE POLE TYPE
BUSHING LENGTH0.219 INCHES MINIMUM AND 0.281 INCHES MAXIMUM
CASE MATERIALPLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.469 INCHES MINIMUM AND 0.531 INCHES MAXIMUM
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
FRAGILITY FACTORMODERATELY RUGGED
FREQUENCY IN HERTZ400.0 SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDCORROSION RESISTANT AND DUSTPROOF AND EXPLOSION PROOF AND FUNGUS RESISTANT AND SALT SPRAY PROOF AND SAND RESISTANT AND SHOCK RESISTANT
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS230.0 AC SINGLE LOCATION
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE1.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1600.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE1.630 INCHES MAXIMUM
NOMINAL THREAD SIZE0.438 INCHES
POLE QUANTITY1
RESET METHODMANUAL
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS0.01 DC
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
SWITCH TERMINAL TYPEPIN
SWITCH VOLTAGE RATING AND TYPE IN VOLTS50.0 DC
TERMINAL TYPE AND QUANTITY2 SCREW
THREAD QUANTITY PER INCH32
THREAD SERIES DESIGNATORUN
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT5.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING77.0 FAHRENHEIT NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
TRIP RELEASE METHODTHERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SINGLE LOCATION
UNPACKAGED UNIT WEIGHT1.500 OUNCES NOMINAL