DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.648 INCHES MINIMUM AND 1.675 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM |
ACTUATOR FUNCTION | TRIP-RESET |
ACTUATOR POSITION DESIGNATION | AT EACH POLE |
ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS | 120.0 DC NOMINAL FIRST LOCATION |
BODY LENGTH | 1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM |
BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
BODY WIDTH | 2.265 INCHES MAXIMUM |
BOSS HEIGHT | 0.115 INCHES MINIMUM AND 0.145 INCHES MAXIMUM |
CASE MATERIAL | PLASTIC |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.648 INCHES MINIMUM AND 1.675 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
CIRCUIT PROTECTION TYPE | OVERCURRENT SECOND LOCATION |
CIRCUIT PROTECTION TYPE | OVERCURRENT THIRD LOCATIONOVERCURRENT SECOND LOCATION |
CIRCUIT PROTECTION TYPE | UNDERVOLTAGE FIRST LOCATION |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
FRAGILITY FACTOR | MODERATELY RUGGED |
FREQUENCY IN HERTZ | 50.0 OR 60.0 SECOND LOCATION50.0 OR 60.0 THIRD LOCATION |
FREQUENCY IN HERTZ | 50.0 OR 60.0 THIRD LOCATION |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCK RESISTANT AND VIBRATION RESISTANT AND SALT SPRAY PROOF AND MOISTURE RESISTANT |
NOMINAL THREAD SIZE | 0.138 INCHES |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 DC FIRST LOCATION |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC THIRD LOCATION250.0 AC SECOND LOCATION |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SECOND LOCATION |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SECOND LOCATION |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP THIRD LOCATIONSERIES TRIP SECOND LOCATION |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP W/REMOTE TRIP FEATURE FIRST LOCATION |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES DC FIRST LOCATION |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES AC SECOND LOCATION |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES AC THIRD LOCATION30.0 AMPERES AC SECOND LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3500.0 AC THIRD LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3500.0 AC SECOND LOCATION |
MOUNTING FACILITY TYPE AND QUANTITY | 8 THREADED HOLE |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.032 INCHES MAXIMUM |
RESET METHOD | MANUAL |
POLE QUANTITY | 3 |
SPECIAL FEATURES | POLE 1 MUST TURN ON WHEN 120 VDC IS APPLIED |
THREAD QUANTITY PER INCH | 32 |
THREAD SERIES DESIGNATOR | UNC |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SECOND LOCATION |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT THIRD LOCATION |
TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS FIRST LOCATION |
TRIP RELEASE DUTY CYCLE | CONTINUOUS FIRST LOCATION |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SECOND LOCATION |
TRIP RELEASE CHARACTERISTIC | TIME DELAY THIRD LOCATIONTIME DELAY SECOND LOCATION |
TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
UNPACKAGED UNIT WEIGHT | 9.000 OUNCES NOMINAL |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 7 THREADED STUD |