5925-01-204-9440 CIRCUIT BREAKER Index 5925-01-204-9442 CIRCUIT BREAKER

National Stock Number:
5925-01-204-9441

Federal Supply Class:
5925

National Item Identification Number:
012049441

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
LS10071B7A98897LOCKHEED MARTIN CORP
SM600BA7A181640SAFRAN POWER USA, LLC


Techincal Specification:
UNTHREADED MOUNTING HOLE DIAMETER0.195 INCHES MINIMUM AND 0.201 INCHES MAXIMUM
SPECIFICATION/STANDARD DATA36659-LS10071 MANUFACTURERS SPECIFICATION CONTROL
SWITCH CONTACT ARRANGEMENTSINGLE POLE, SINGLE THROW, NORMALLY CLOSED
SWITCH CURRENT RATING AND TYPE IN AMPS7.5 AC
SWITCH LOCATION AND POSITION DESIGNATIONEXTERNAL AT POLE ONE
SWITCH TERMINAL TYPEWIRE LEAD
SWITCH VOLTAGE RATING AND TYPE IN VOLTS110.0 AC
TERMINAL TYPE AND QUANTITY2 TAB W/SCREW
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.927 INCHES MINIMUM AND 2.947 INCHES MAXIMUM
AUXILIARY SWITCH FUNCTION AND QUANTITY1 CONTROL
AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS110.0 AC NOMINAL SINGLE LOCATION
BODY STYLESINGLE POLE TYPE
BODY WIDTH1.250 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.531 INCHES NOMINAL
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
FEATURES PROVIDEDTRIP INDICATOR
MOUNTING SURFACE TO TERMINAL END DISTANCE4.250 INCHES NOMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS115.0 AC SINGLE LOCATION
OVERALL LENGTH3.375 INCHES MAXIMUM
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP W/REMOTE TRIP FEATURE SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPENONTRIP FREE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE7.5 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS2800.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
POLE QUANTITY1
RESET ACTUATOR VOLTAGE RATING AND TYPE IN VOLTS110.0 AC
RESET METHODELECTRIC
TRIP RELEASE AMBIENT TEMP RATING25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE DUTY CYCLECONTINUOUS SINGLE LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
TRIP RELEASE METHODTHERMAL SINGLE LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT13.000 MINIMUM AT 200 PCT AND 60.000 MAXIMUM AT 200 PCT SINGLE LOCATION
ULTIMATE TRIP TIME PER POLE IN SECONDS360.000 MAXIMUM SINGLE LOCATION