ACTUATOR FUNCTION | RESET |
ACTUATOR POSITION DESIGNATION | BETWEEN POLE ONE AND TWO |
BODY LENGTH | 1.500 INCHES MAXIMUM |
BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
BODY WIDTH | 1.250 INCHES MAXIMUM |
BUSHING LENGTH | 0.380 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.825 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.625 INCHES NOMINAL |
CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC ALL LOCATIONS |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC ALL LOCATIONS |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500.0 DC ALL LOCATIONS |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.780 INCHES MAXIMUM |
NOMINAL THREAD SIZE | 0.375 INCHES |
POLE QUANTITY | 2 |
RESET METHOD | MANUAL |
TERMINAL TYPE AND QUANTITY | 4 WIRE HOOK |
THREAD PITCH DIAMETERS | +0.3503 TO 0.3537 INCHES |
THREAD SERIES DESIGNATOR | UNEF |
THREAD QUANTITY PER INCH | 32 |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.080 MINIMUM AT 200 PCT AND 0.600 MAXIMUM AT 200 PCT AND 0.020 MINIMUM AT 300 PCT AND 0.200 MAXIMUM AT 300 PCT AND 0.010 MINIMUM AT 400 PCT AND 0.080 MAXIMUM AT 400 PCT ALL LOCATIONS |
TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |