5945-00-971-1117 SOLENOID,ELECTRICAL Index 5999-00-971-1121 RELAY-SWITCH

National Stock Number:
5925-00-971-1120

Federal Supply Class:
5925

National Item Identification Number:
009711120

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
228-1332P13B150RAYTHEON COMPANY
228-1332P149956RAYTHEON COMPANY
NE231100NAASE202201CHALLENGER ACQUISITION CORP ENGINEERED DISTRIBUTION PRODUCTS DIV
NE231100NAASE279443FEDERAL PACIFIC ELECTRIC CO ST LOUIS PANELBOARD PLANT
NE233100NAASE279443FEDERAL PACIFIC ELECTRIC CO ST LOUIS PANELBOARD PLANT
NE234100NAAE279443FEDERAL PACIFIC ELECTRIC CO ST LOUIS PANELBOARD PLANT
S228-1332P13B150RAYTHEON COMPANY
S228-1332P149956RAYTHEON COMPANY


Techincal Specification:
ACTUATOR POSITION DESIGNATIONBETWEEN POLE ONE AND TWO
BODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH4.125 INCHES NOMINAL
BOSS HEIGHT0.438 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH5.219 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.375 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH5.219 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.688 INCHES NOMINAL
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
MATERIALPLASTIC CASE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE100.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS18000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC ALL LOCATIONS
POLE QUANTITY3
TERMINAL TYPE AND QUANTITY6 EYELET
UNTHREADED MOUNTING HOLE DIAMETER0.225 INCHES NOMINAL


Click here to Register for Free 30-day Trial