5965-00-756-0457 MICROPHONE ELEMENT Index 6145-00-756-0463 CABLE,SPECIAL PURPOSE,ELECTRICAL

National Stock Number:
5925-00-756-0462

Federal Supply Class:
5925

National Item Identification Number:
007560462

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
2105C79405WOOD ELECTRIC OPERATIONS POTTER AND BRUMFIELD DIV AMF INC
613540-198897LOCKHEED MARTIN CORP


Techincal Specification:
ACTUATOR FUNCTIONRESET
ARC QUENCHING METHODAIR
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDEXPLOSION PROOF AND DUSTPROOF
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH BUTTON
OVERALL HEIGHT1.094 INCHES NOMINAL
OVERALL LENGTH2.317 INCHES NOMINAL
OVERALL WIDTH0.750 INCHES NOMINAL
MATERIALPLASTIC CASE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE5.0 AMPERES AC AND 5.0 AMPERES DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
NOMINAL THREAD SIZE0.469 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS200.0 AC AND 28.0 DC SINGLE LOCATION
POLE QUANTITY1
PRECIOUS MATERIALSILVER
RESET METHODMANUAL
TERMINAL TYPE AND QUANTITY2 SCREW
THREAD QUANTITY PER INCH32
THREAD SERIES DESIGNATORUNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT15.000 MINIMUM AT 200 PCT AND 55.000 MAXIMUM AT 200 PCT AND 2.000 MINIMUM AT 400 PCT AND 7.000 MAXIMUM AT 400 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING25.0 CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
TRIP RELEASE METHODMAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0 SINGLE LOCATION


Click here to Register for Free 30-day Trial