ACTUATOR FUNCTION | RESET |
ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC SINGLE LOCATION |
OVERALL HEIGHT | 2.570 INCHES NOMINAL |
OVERALL LENGTH | 1.750 INCHES NOMINAL |
OVERALL WIDTH | 0.630 INCHES NOMINAL |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 2.0 AMPERES AC SINGLE LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500.0 AC SINGLE LOCATION |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
NOMINAL THREAD SIZE | 0.375 INCHES |
POLE QUANTITY | 1 |
RESET METHOD | MANUAL |
TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK |
THREAD SERIES DESIGNATOR | UNEF |
THREAD QUANTITY PER INCH | 32 |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.150 MINIMUM AT 200 PCT AND 0.800 MAXIMUM AT 200 PCT AND 0.050 MINIMUM AT 300 PCT AND 0.370 MAXIMUM AT 300 PCT AND 0.010 MINIMUM AT 400 PCT AND 0.190 MAXIMUM AT 400 PCT SINGLE LOCATION |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |